MPRXCX® FLEXISHIP® EMC
0.6/1(1.2) kV
MPRXCX® FLEXISHIP® EMC 0.6/1kV 3x16
Nexans ref.
- Packaging: Cut to length (m)
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 16 mm²
- Minimum outer diameter: 18.0 mm
- Maximum outer diameter: 20.5 mm
- Approximate weight: 790 kg/km
MPRXCX® FLEXISHIP® EMC 0.6/1kV 3x25
Nexans ref.
- Packaging: Cut to length (m)
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 25 mm²
- Minimum outer diameter: 22.5 mm
- Maximum outer diameter: 25.0 mm
- Approximate weight: 1140 kg/km
MPRXCX® FLEXISHIP® EMC 0.6/1kV 3x35
Nexans ref.
- Packaging: Cut to length (m)
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 35 mm²
- Minimum outer diameter: 25.0 mm
- Maximum outer diameter: 28.5 mm
- Approximate weight: 1530 kg/km
MPRXCX® FLEXISHIP® EMC 3x50
Nexans ref. 10280564
- Packaging: Cut to length (m)
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 50 mm²
- Minimum outer diameter: 24.5 mm
- Maximum outer diameter: 30.5 mm
- Approximate weight: 1974 kg/km
MPRXCX® FLEXISHIP® EMC 0.6/1kV 3x70
Nexans ref.
- Packaging: Cut to length (m)
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 70 mm²
- Minimum outer diameter: 36.5 mm
- Maximum outer diameter: 39.5 mm
- Approximate weight: 3205 kg/km
MPRXCX® FLEXISHIP® EMC 0.6/1kV 3x95
Nexans ref.
- Packaging: Cut to length (m)
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 95 mm²
- Minimum outer diameter: 40.0 mm
- Maximum outer diameter: 44.0 mm
- Approximate weight: 4062 kg/km
MPRXCX® FLEXISHIP® EMC 3x120
Nexans ref. 10282645
- Packaging: Cut to length (m)
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 120 mm²
- Minimum outer diameter: 45.0 mm
- Maximum outer diameter: 49.5 mm
- Approximate weight: 4135 kg/km
MPRXCX® FLEXISHIP® EMC 0.6/1kV 3x185
Nexans ref. 10239793
- Packaging: Cut to length (m)
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 185 mm²
- Minimum outer diameter: 54.5 mm
- Maximum outer diameter: 60.0 mm
- Approximate weight: 7320 kg/km
MPRXCX® FLEXISHIP® EMC 4G2,5
Nexans ref. 10280406
- Packaging: Cut to length (m)
- With Green/Yellow core: Yes
- Number of cores: 4
- Conductor cross-section: 2.5 mm²
- Minimum outer diameter: 11.0 mm
- Maximum outer diameter: 13.0 mm
- Approximate weight: 222 kg/km
MPRXCX® FLEXISHIP® EMC 4G4
Nexans ref.
- Packaging: Cut to length (m)
- With Green/Yellow core: Yes
- Number of cores: 4
- Conductor cross-section: 4 mm²
- Minimum outer diameter: 12.5 mm
- Maximum outer diameter: 15.0 mm
- Approximate weight: 287 kg/km
MPRXCX® FLEXISHIP® EMC 4G6
Nexans ref. 10280407
- Packaging: Cut to length (m)
- With Green/Yellow core: Yes
- Number of cores: 4
- Conductor cross-section: 6 mm²
- Minimum outer diameter: 15.0 mm
- Maximum outer diameter: 17.5 mm
- Approximate weight: 423 kg/km
MPRXCX® FLEXISHIP® EMC 3x16+3G2,5
Nexans ref. 10280408
- Packaging: Cut to length (m)
- With Green/Yellow core: Yes
- Number of cores: 4
- Conductor cross-section: 16 mm²
- Minimum outer diameter: 20.5 mm
- Maximum outer diameter: 23.5 mm
- Approximate weight: 878 kg/km
MPRXCX® FLEXISHIP® EMC 3x25+3G4
Nexans ref. 10280409
- Packaging: Cut to length (m)
- With Green/Yellow core: Yes
- Number of cores: 4
- Conductor cross-section: 25 mm²
- Minimum outer diameter: 22.0 mm
- Maximum outer diameter: 26.5 mm
- Approximate weight: 1244 kg/km
MPRXCX® FLEXISHIP® EMC 3x35+3G6
Nexans ref. 10282483
- Packaging: Cut to length (m)
- With Green/Yellow core: Yes
- Number of cores: 4
- Conductor cross-section: 35 mm²
- Minimum outer diameter: 27.8 mm
- Maximum outer diameter: 32.0 mm
- Approximate weight: 1728 kg/km
MPRXCX® FLEXISHIP® EMC 3x50+3G10
Nexans ref. 10280410
- Packaging: Cut to length (m)
- With Green/Yellow core: Yes
- Number of cores: 4
- Conductor cross-section: 50 mm²
- Minimum outer diameter: 29.5 mm
- Maximum outer diameter: 32.5 mm
- Approximate weight: 2321 kg/km
MPRXCX® FLEXISHIP® EMC 3x70+3G10
Nexans ref. 10280523
- Packaging: Cut to length (m)
- With Green/Yellow core: Yes
- Number of cores: 4
- Conductor cross-section: 70 mm²
- Minimum outer diameter: 36.5 mm
- Maximum outer diameter: 40.5 mm
- Approximate weight: 3171 kg/km
MPRXCX® FLEXISHIP® EMC 3x70+3G16
Nexans ref. 10281396
- Packaging: Cut to length (m)
- With Green/Yellow core: Yes
- Number of cores: 4
- Conductor cross-section: 70 mm²
- Minimum outer diameter: 35.0 mm
- Maximum outer diameter: 38.5 mm
- Approximate weight: 3317 kg/km
MPRXCX® FLEXISHIP® EMC 3x95+3G16
Nexans ref. 10280522
- Packaging: Cut to length (m)
- With Green/Yellow core: Yes
- Number of cores: 4
- Conductor cross-section: 95 mm²
- Minimum outer diameter: 40.5 mm
- Maximum outer diameter: 44.5 mm
- Approximate weight: 4012 kg/km
MPRXCX® FLEXISHIP® EMC 3x120+3G25
Nexans ref. 10281395
- Packaging: Cut to length (m)
- With Green/Yellow core: Yes
- Number of cores: 4
- Conductor cross-section: 120 mm²
- Minimum outer diameter: 45.0 mm
- Maximum outer diameter: 49.0 mm
- Approximate weight: 4998 kg/km
MPRXCX® FLEXISHIP® EMC 3x150+3G25
Nexans ref.
- Packaging: Cut to length (m)
- With Green/Yellow core: Yes
- Number of cores: 4
- Conductor cross-section: 150 mm²
- Minimum outer diameter: 49.5 mm
- Maximum outer diameter: 54.5 mm
- Approximate weight: 6680 kg/km
Description
Description
Standards
-
ProductIEC 60228
-
InstallationIEC 60092-350; IEC 60092-353; IEC 60092-360
-
TestIEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034
Application
Motor supply cable for frequency converters controlled low voltage AC drives on ships, called VFD applications. MPRXCX® FLEXISHIP® EMC cables are designed with a special coverage, copper-polyester tape and braid, which provide a 100% EMC protection. Insulation with low dielectric constant is used to reduce reflected wave voltage peak magnitude.
Symmetrical insulated ground wires, placed in corner, can reduce reflected wave and return common mode noisy currents back to the drive. Enhanced insulation is implemented for 0.6/1 (1.2) kV cable to fulfil periodic peak voltage up to 2xU=2 kV due to harmonics.
These cables are used on board of ships in all locations for fixed installations.
Design
- Conductor:
Flexible bare copper class 5
Stranded bare copper class 2 for cross-section < 4 mm² - Insulation:
XLPE (cross linked polyethylene) - Optional
Return earth conductor - Assempling:
Polyester tape - Screen / Armouring:
Copper / polyester tape
Bare copper braid - Outer sheath:
Polyolefin SHF1 (SHF2 on request)
Colour: black
Marking
NEXANS 279 MPRXCX FLEXISHIP EMC Nber of cores & cross-section 0.6/1 kV 90C
IEC 60092-353 IEC 60332-22 Cat. A SS YYYY *CE* Manufacturing n° + metric marking
Core Identification
3 cores: black-grey-brown
Earth: green/yellow split in 3 conductors
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania